ECL202

ECL202

Get highest precision from this sensor with a digital core and push button controls.

Key Benefits
  • Ranges from 0.25 mm to 15 mm
  • Industry standard 0-10 VDC Output
  • Setpoint Contacts Output
  • CE Compliant
  • Versatile, Useful Features
  • Probe can be used in wet, dirty environments
  • Push-Button Offset
  • Push-Button Switch Threshold (Setpoint)
  • Range Indicating LEDs
  • Remote Offset and Threshold Activation
  • User-Selectable Bandwidth/Resolution 100 Hz, 1 kHz, 10 kHz, 15 kHz (not available on ‘e’ version)
  • Probes can be ordered as vacuum compatible
Specifications

Typical specifications for standard targets and probes. Actual values depend on probe, target, and calibration. Specifications assume a target area at least three times the diameter of the probe.

  • Resolution: RMS, Typical Dependent on probe and range.
    • ECL202:
      • Nonferrous: 15 kHz – 0.007% | 100 Hz – 0.002%
      • Ferrous: 15 kHz – 0.009% | 100 Hz – 0.003%
    • ECL202e:
      • See Range Table
  • Bandwidth:
    • ECL202: Selectable: 100 Hz | 1 kHz | 10 kHz | 15 kHz
    • ECL202e: 15 kHz
  • Ranges: 0.25 mm to 15.0 mm
  • Linearity: 0.2% of Range
  • Error Band: 0.4% of Range
  • Driver Temperature Drift (15°C-50°C): 0.01% F.S./°C
  • Probe Temperature Drift (15°C-65°C, except where noted): 0.01% F.S./°C
  • Analog Output: 0-10 VDC, 0 Ω, 15 mA
  • Switched Output: 30 VAC/60 VDC/100 mA
  • Input Power: 15-24 VDC | 2.5  W
  • Driver Operating Environment: 4°C – 50°C | IP40
  • Probe Operating Environment:
    • Standard Probes come with PUR (Polyurethane) jacketed cables. High Temperature Probes have FEP jackets. Other temperature ranges may be possible. Contact us for more information. Standard Probes: IP67 | High Temperature Probes: IP63
      • U3 Probe: Standard Probe (PUR Cable): -25°C to +125°C (Available with optional FEP cable) | High Temperature Version Not Available
      • U5-18 Probes: Standard Probes: -25°C to +125°C | High Temperature Probes: -25°C to +200°C
      • U25-50 Probes: Standard Probes: -25°C to +125°C | High Temperature Probes: -25°C to +175°C
  • Zero/Offset Adjust:  Push-Button
​Contact us today for custom-designed products to deliver elite speed and precision across your application.