ECA110

ECA110

Low-cost sensing solution for high-quantity OEM applications.

Key Benefits
  • Plug-in PCB
  • Factory Calibrated and Ready to Install
  • Embedded Systems
  • Minimum Quantities Required
  • Probes can be ordered as vacuum compatible
Specifications

Typical specifications for standard targets and probes. Actual values depend on probe, target, and calibration.

  • Resolution: RMS at mid-range at 10 kHz for most calibrations: 0.02% of range RMS
    • Typical Resolution @10 kHz: Nonferrous 0.02%, Ferrous 0.02%
  • Bandwidth:  10 kHz
  • Range: 0.50 mm to 15.0 mm
  • Linearity:  Nonlinear
  • Temperature Drift of Probe at mid-range: 0.2% of range/°C
  • Voltage Output: Analog Voltage: 0-10 V
  • Input Power: 12-24 VDC 30 mA @ 15V
  • Operating Temperature: 4°C-50°C
  • Probe Operating Environment:
    • Standard Probes come with PUR (Polyurethane) jacketed cables. High Temperature Probes have FEP jackets. Other temperature ranges may be possible. Contact us for more information. Standard Probes: IP67 | High Temperature Probes: IP63
      • U3 Probe: Standard Probe (PUR Cable): -25°C to +125°C (Available with optional FEP cable) | High Temperature Version Not Available
      • U5-18 Probes: Standard Probes: -25°C to +125°C | High Temperature Probes: -25°C to +200°C
      • U25-50 Probes: Standard Probes: -25°C to +125°C | High Temperature Probes: -25°C to +175°C
  • Zero/Offset Adjust:  No
​Contact us today for custom-designed products to deliver elite speed and precision across your application.